Brocade Network OS Message Reference v4.1.1 Manuale Utente Pagina 165

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 478
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 164
Network OS Message Reference 149
53-1003227-01
EANV-1004
8
EANV-1004
Message C<chip index>: Invalid DMA ch pointer, chan:<Channel number>, good_addr:0x<Good
address> bad_addr:0x<Bad address>.
Message Type LOG
Severity ERROR
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
No action is required. The software will recover from the error.
EANV-1005
Message C<chip index>,A<eanvil id>: Memory allocation failed.
Message Type LOG
Severity ERROR
Probable Cause Indicates memory allocation failure in the software.
Recommended
Action
Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.
EANV-1006
Message C<chip index>: HW ASIC Chip fault. Type = 0x<chip error type>, Error = <chip error
string>.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip not operational.
Recommended
Action
Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.
Vedere la pagina 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 477 478

Commenti su questo manuale

Nessun commento