Brocade Network OS Message Reference v4.1.1 Manuale Utente Pagina 442

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 478
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 441
426 Network OS Message Reference
53-1003227-01
TNLD-1000
8
TNLD Messages
TNLD-1000
Message TunnelMgr initialized successfully.
Message Type LOG
Severity INFO
Probable Cause Indicates that the Data Center Ethernet (DCE) tunnel manager has been initialized.
Recommended
Action
No action is required.
TNLD-1001
Message Failed to allocate memory: (<function name>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the show process memory command.
Restart or power cycle the switch.
TNLD-1005
Message TunnelMgr startup failed.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the Data Center Ethernet (DCE) tunnel manager encountered an unexpected severe error
during basic startup and initialization.
Recommended
Action
Restart or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.
Vedere la pagina 441
1 2 ... 437 438 439 440 441 442 443 444 445 446 447 ... 477 478

Commenti su questo manuale

Nessun commento