Network OS Message Reference 83
53-1003227-01
AG-1034
8
Recommended
Action
No action is required.
AG-1034
Message VF_Port cannot accept any more logins (<fport>).
Message Type LOG
Severity INFO
Probable Cause Indicates that the VF_Port already has logged in the maximum number of devices.
Recommended
Action
No action is required.
AG-1038
Message FCoE AG Ports going to different fabrics, Check N Port (<domain>/<blade>/<port>).
Message Type LOG
Severity ERROR
Probable Cause Indicates a misconfiguration.
Recommended
Action
Connect all ports in the port group to the same fabric.
AG-1040
Message No N_Port(s) are currently Online in PG <PG that has no N ports online>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that no N_Ports are currently configured in the system or all configured N_Ports have failed to
come online.
Recommended
Action
Check the status of the N_Ports in the port group.